Siemens Solid Edge

View CSAF

Summary

Solid Edge uses PS/IGES Parasolid Translator Component that contains an out of bounds read that could be triggered when the application reads files in IGS file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Solid Edge and recommends to update to the latest version.

The following versions of Siemens Solid Edge are affected:

  • Solid Edge: All versions prior to V226.00 Update 03
CVSS Vendor Equipment Vulnerabilities
v3 7.8 Siemens Siemens Solid Edge Out-of-bounds Read

Background

  • Critical Infrastructure Sectors: Critical Manufacturing
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Germany

Vulnerabilities

Expand All +

CVE-2025-40936

The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755)

View CVE Details


Affected Products

Siemens Solid Edge
Vendor:
Siemens
Product Version:
Solid Edge
Product Status:
known_affected
Remediations

Vendor fix
Update to V226.00 Update 03 or later version

Relevant CWE: CWE-125 Out-of-bounds Read


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Acknowledgments

  • Siemens ProductCERT reported this vulnerability to CISA.
  • Trend Micro Zero Day Initiative reported this vulnerability to Siemens.

General Recommendations

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens’ operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity


Additional Resources

For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories


Terms of Use

The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.


Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


Recommended Practices

CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.

Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.

Locate control system networks and remote devices behind firewalls and isolate them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be up

[…]
Content was cut in order to protect the source.Please visit the source for the rest of the article.

This article has been indexed from All CISA Advisories

Read the original article: