Siemens SINEC NMS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINEC NMS
  • Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Limitation of a Pathname to a Restricted Directory

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to impact confidentiality, integrity, and availability.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

  • SINEC NMS: All versions prior to V2.0 SP2

3.2 Vulnerability Overview

3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial-of-Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() does n

[…]
Content was cut in order to protect the source.Please visit the source for the rest of the article.

This article has been indexed from All CISA Advisories

Read the original article: