Siemens COMOS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: COMOS
  • Vulnerabilities: Out-of-bounds Write, Use After Free

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens COMOS, a unified data platform, are affected:

  • COMOS: All versions prior to V10.5

3.2 Vulnerability Overview

3.2.1 OUT-OF-BOUNDS WRITE CWE-787

An issue was discovered in Open Design Alliance Drawings SDK before 2024.12. A corrupted value of number of sectors used by the Fat structure in a crafted DGN file leads to an out-of-bounds write. An attacker can leverage this vulnerability to execute code in the context of the current process.

CVE-2023-5180 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).