1. EXECUTIVE SUMMARY
- CVSS v4 9.2
- ATTENTION: Exploitable remotely/Low attack complexity
- Vendor: Dover Fueling Solutions
- Equipment: ProGauge MagLink LX consoles
- Vulnerability: Missing Authentication for Critical Function
2. RISK EVALUATION
Successful exploitation of this vulnerability could result in an attacker gaining control of the monitoring device, manipulating fueling operations, deleting system configurations, or deploying malware.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of ProGauge MagLink LX, a fuel and water tank monitor, are affected:
- ProGauge MagLink LX 4: Versions prior to 4.20.3
- ProGauge MagLink LX Plus: Versions prior to 4.20.3
- ProGauge MagLink LX Ultimate: Versions prior to 5.20.3
3.2 VULNERABILITY OVERVIEW
3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
The device exposes an undocumented and unauthenticated Target Communication Framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
CVE-2025-5310 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-5310. A base score of 9.2 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND[…]