Delta Electronics ASDA-Soft

View CSAF

Summary

Successful exploitation of this vulnerability may allow an attacker to write arbitrary data beyond the bounds of a stack-allocated buffer, leading to the corruption of a structured exception handler (SEH).

The following versions of Delta Electronics ASDA-Soft are affected:

  • ASDA-Soft <=7.2.0.0 (CVE-2026-1361)
CVSS Vendor Equipment Vulnerabilities
v3 7.8 Delta Electronics Delta Electronics ASDA-Soft Stack-based Buffer Overflow

Background

  • Critical Infrastructure Sectors: Critical Manufacturing
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Taiwan

Vulnerabilities

Expand All +

CVE-2026-1361

A stack-based buffer overflow vulnerability exists in ASDA_Soft version 7.2.0.0 when parsing .par files. The root cause is the improper validation of a user-controlled size parameter, which is checked incorrectly against the upper limits of the local buffer. This allows data to be written past the end of the buffer.

View CVE Details


Affected Products

Delta Electronics ASDA-Soft
Vendor:
Delta Electronics
Product Version:
Delta Electronics ASDA-Soft: <=7.2.0.0
Product Status:
known_affected
Remediations

Mitigation
Delta has fixed this vulnerability and released a new version v7.2.2.0 at Delta Download Center (https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=asda-soft&sort_expr=cdate&sort_dir=DESC).
https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&q=asda-soft&sort_expr=cdate&sort_dir=DESC

Mitigation
For more information, see Delta Electronics advisory Delta-PCSA-2026-00003 at https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory
https://www.deltaww.com/en-US/service-support/product-cybersecurity/advisory

Mitigation
Delta Electronics provides the following general recommendations: Do not click on untrusted internet links or open unsolicited attachments in emails. Avoid exposing control systems and equipment to the Internet. Place control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use a secure access method, such as a virtual private network (VPN).
If you have any product-related support concerns, contact Delta via the portal page(https://www.deltaww.com/en-US/service-support/contact-us?type=1) for any information or materials you may require.
https://www.deltaww.com/en-US/service-support/contact-us?type=1

Relevant CWE: CWE-121 Stack-based Buffer Overflow


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Acknowledgments

  • nisu of Trend Research reported this vulnerability to CISA

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


Recommended Practices

CISA recommends users take defensive measures to minimize the risk o

[…]
Content was cut in order to protect the source.Please visit the source for the rest of the article.

This article has been indexed from All CISA Advisories

Read the original article: