ABB Ability Symphony Plus Engineering

View CSAF

Summary

ABB became aware of vulnerability in the products versions listed as affected in the advisory. The ABB S+ Engineering product versions are affected by vulnerabilities in PostgreSQL version 13.11 and earlier versions. If an attacker gains access to a site’s S+ Client Server network, they could exploit such vulnerabilities by executing arbitrary code and potentially compromising the entire system.

The following versions of ABB Ability Symphony Plus Engineering are affected:

  • Ability Symphony Plus 2.2, 2.3, 2.3_RU1, 2.3_RU2, 2.3_RU3, 2.4, 2.4_SP1, 2.4_SP2, 2.4_SP2_RU1 
CVSS Vendor Equipment Vulnerabilities
v3 8.8 ABB ABB Ability Symphony Plus Engineering Integer Overflow or Wraparound, Improper Neutralization of Special Elements used in an SQL Command (‘SQL Injection’), Time-of-check Time-of-use (TOCTOU) Race Condition, Privilege Dropping / Lowering Errors

Background

  • Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Switzerland

Vulnerabilities

Expand All +

CVE-2023-5869

An attacker running as an authenticated PostgreSQL user can provide crafted data and trigger the integer overflow due to such missing overflow check. This can enable the execution of arbitrary code in the system.

View CVE Details


Affected Products

ABB Ability Symphony Plus Engineering
Vendor:
ABB
Product Version:
ABB Ability Symphony Plus S+ Engineering 2.2, ABB Ability Symphony Plus S+ Engineering 2.3, ABB Ability Symphony Plus S+ Engineering 2.3 RU1, ABB Ability Symphony Plus S+ Engineering 2.3 RU2, ABB Ability Symphony Plus S+ Engineering 2.3 RU3, ABB Ability Symphony Plus S+ Engineering 2.4, ABB Ability Symphony Plus S+ Engineering 2.4 SP1, ABB Ability Symphony Plus S+ Engineering 2.4 SP2
Product Status:
fixed, known_affected
Remediations

Vendor fix
ABB advises all customers to review their installations to determine if they are using an impacted product as listed above, no further analysis or tools are needed to make this determination. The recommended immediate actions per product are listed below: – Systems using S+ Engineering 2.2 through 2.4 SP2 should upgrade to S+ Engineering 2.4 SP2 RU1 (re-leased in December 2024) or later. – End users who are unable to install one of these updates should immediately look to implement the Mitigation and Workarounds listed below as this will restrict or prevent an attacker’s ability to com-promise the system. ABB recommends that customers apply the update at the earliest convenience.

Mitigation
Any exploit of these vulnerabilities would require that the attacker has access to the site’s S+ client/server network. Following ABB’s recommended security practices, including network architecture and perimeter firewall, are mitigating factors in preventing external access to the S+ client/server net-work. Refer to section “General security recommendations” for further advise on how to keep your system secure.

Workaround
No workarounds are available. Assess the installation specific risk based on this advisory. Use the recommendations described under “Mitigating factors” or “Recommended immediate actions”.

Relevant CWE: CWE-190 Integer Overflow or Wraparound


Metrics

[…]
Content was cut in order to protect the source.Please visit the source for the rest of the article.

This article has been indexed from All CISA Advisories

Read the original article:

CVSS Version Base Score Base Severity Vector String
3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C