Siemens RUGGEDCOM CROSSBOW Station Access Controller

View CSAF

Summary

RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version.

The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected:

  • RUGGEDCOM CROSSBOW Station Access Controller (SAC) vers:intdot/<6.0 (CVE-2025-6965, CVE-2025-70873, CVE-2025-71316, CVE-2026-11822, CVE-2026-11824)

CVSS
Vendor
Equipment

v3 9.8
Siemens
RUGGEDCOM CROSSBOW Station Access Controller (SAC)

4 Vulnerabilities

Numeric Truncation Error, Improper Clearing of Heap Memory Before Release ('Heap Inspection'), Improper Handling of Unicode Encoding, Heap-based Buffer Overflow

Background

  • Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Germany

Vulnerabilities
Expand All +

CVE-2025-6965
There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above.
Read More

1 Affected Product

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

Additional Metrics

Relevant CWE: CWE-197 Numeric Truncation Error

CVSS Version
Base Score
Base Severity
Vector String

3.1
7.7
HIGH
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L

View CVE Details

CVE-2025-70873
An information disclosure issue in the zipfileInflate function in the zipfile extension in SQLite v3.51.1 and earlier allows attackers to obtain heap memory via supplying a crafted ZIP file.
Read More

2 Affected Products

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

Additional Metrics

Relevant CWE: CWE-244 Improper Clearing of Heap Memory Before Release ('Heap Inspection')

CVSS Version
Base Score
Base Severity
Vector String

3.1
7.5
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

View CVE Details

CVE-2025-71316
SQLite 'sqldiff.exe' does not securely handle the way the Microsoft Windows C runtime converts Unicode characters to ANSI codepages. An attacker could use the '-L' option to load an arbitrary DLL with a crafted command line argument string that results in command line file arguments being misinterpreted as command line options. Fixed on or around 2025-12-26.
Read More

3 Affected Products

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

Additional Metrics

Relevant CWE: CWE-176 Improper Handling of Unicode Encoding

CVSS Version
Base Score
Base Severity
Vector String

3.1
9.8
CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

View CVE Details

CVE-2026-11822
SQLite before 3.53.2 contains memory corruption vulnerabilities in the FTS5 full-text search extension that allow attackers to cause process crashes, memory exhaustion, or arbitrary code execution by supplying a crafted database with malformed FTS5 page data. Attackers can trigger an out-of-bounds read in fts5LeafSeek() via an attacker-controlled loop bound and a heap buffer overflow write in fts5ChunkIterate() through a crafted continuation page causing an integer underflow, exploitable when an FTS5 MATCH query is executed against the malicious database.
Read More

4 Affected Products

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0

Product Status: known_affected

Remediations

Vendor fix
Update to V6.0 or later version

Additional Metrics

Relevant CWE: CWE-122 Heap-based Buffer

[…]
Content was trimmed to protect the source. Please visit the original article for the full text.

This article has been indexed from All CISA Advisories