Siemens RUGGEDCOM APE1808 Devices Configured with Palo Alto Networks Virtual NGFW

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 
View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM APE1808
  • Vulnerability: Command Injection

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code with root privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens RUGGEDCOM APE1808, an application hosting platform, are affected:

  • RUGGEDCOM APE1808: All versions with Palo Alto Networks Virtual NGFW configured with GlobalProtect gateway or GlobalProtect portal (or both).

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

A command injection as a result of arbitrary file creation vulnerability in the GlobalProtect feature of Palo Alto Networks PAN-OS software for specific PAN-OS versions and distinct feature configurations may enable an unauthenticated attacker to execute arbitrary code with root privileges on the firewall.

CVE-2024-3400 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (This article has been indexed from All CISA Advisories

Read the original article:

Siemens RUGGEDCOM APE1808 Devices Configured with Palo Alto Networks Virtual NGFW