Siemens Industrial Edge App Publisher

View CSAF

Summary

The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version.

The following versions of Siemens Industrial Edge App Publisher are affected:

  • Industrial Edge App Publisher vers:intdot/<1.27.9 (CVE-2026-78556, CVE-2026-78557)

CVSS
Vendor
Equipment

v3 8.3
Siemens
Industrial Edge App Publisher

2 Vulnerabilities

Improper Certificate Validation, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Background

  • Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: Germany

Vulnerabilities
Expand All +

CVE-2026-78556
The affected software does not properly validate the server certificate when initiating a TLS connection. This allows an attacker to intercept and relay communication (Man-in-the-Middle attack) and to spoof a trusted entity by interfering in the communication path between the client and the intended server.
Read More

1 Affected Product

Industrial Edge App Publisher < V1.27.9

Product Status: known_affected

Remediations

Vendor fix
Update to V1.27.9 or later version

Additional Metrics

Relevant CWE: CWE-295 Improper Certificate Validation

CVSS Version
Base Score
Base Severity
Vector String

3.1
7.4
HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N

View CVE Details

CVE-2026-78557
The application fails to properly sanitize or escape data received from the backend before rendering it in the user interface. Because the front end is integrated with Node.js, this vulnerability allows for the execution of arbitrary JavaScript, which can be leveraged to achieve remote code execution (RCE) on the victim's machine
Read More

2 Affected Products

Industrial Edge App Publisher < V1.27.9

Product Status: known_affected

Remediations

Vendor fix
Update to V1.27.9 or later version

Industrial Edge App Publisher < V1.27.9

Product Status: known_affected

Remediations

Vendor fix
Update to V1.27.9 or later version

Additional Metrics

Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

CVSS Version
Base Score
Base Severity
Vector String

3.1
8.3
HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H

View CVE Details

Acknowledgments

  • Siemens ProductCERT reported these vulnerabilities to CISA.

General Recommendations

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Additional Resources

For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories

Terms of Use

The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation

[…]
Content was trimmed to protect the source. Please visit the original article for the full text.

This article has been indexed from All CISA Advisories

Read the original article:

Siemens Industrial Edge App Publisher