Siemens is currently assessing the impact of Node2Shell (CVE-2026-111497) on Industrial Edge. Please check your Industrial Edge Management (IEM) setup: – No Management Applications installed: No action is required. Although the affected Brotli library is included in the IEM software stack, the affected functionality is not used or exposed. The same applies to IEDK. – Management Applications installed: Follow the specific mitigations until a fix is available. – Device Applications installed: Follow the specific mitigations until a fix is available. For Siemens-managed services, Industrial Edge Hub and Industrial Edge Management Cloud, appropriate Firewall/WAF protection has already been implemented. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available.
The following versions of Siemens Industrial Edge Management are affected:
- Cloud Connector Configurator vers:intdot/<1.24.3 (CVE-2026-111497)
- Common Configurator (CC on IEM) vers:all/* (CVE-2026-111497)
- Common Configurator on Device (CC on Edge) vers:all/* (CVE-2026-111497)
- Data Flow Monitoring vers:intdot/<3.0.18 (CVE-2026-111497)
- Databus Configurator vers:intdot/<4.0.1 (CVE-2026-111497)
- DataXess Configurator vers:intdot/<1.5.7 (CVE-2026-111497)
- Edge OPC UA Server Configurator vers:intdot/<2.3.10 (CVE-2026-111497)
- Flow Creator Configurator vers:intdot/<1.15.1 (CVE-2026-111497)
- Industrial Edge Hub vers:all/* (CVE-2026-111497)
- Industrial Edge Management Cloud vers:all/* (CVE-2026-111497)
CVSS
Vendor
Equipment
v3 9.8
Siemens
Cloud Connector Configurator
1 Vulnerability
Out-of-bounds Write
Background
- Critical Infrastructure Sectors: Critical Manufacturing
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Germany
Vulnerabilities
CVE-2026-111497
A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
Read More
10 Affected Products
Cloud Connector Configurator < V1.24.3
Product Status: known_affected
Remediations
Vendor fix
Update to V1.24.3 or later version
Industrial Edge Management Cloud
Product Status: known_affected
Remediations
Vendor fix
Vulnerability fixed on central cloud service starting 2026-10-28; no user actions necessary
Common Configurator (CC on IEM)
Product Status: known_affected
Remediations
Mitigation
Uninstall all Management Applications and protect your IEM instance with a Firewall/WAF until a fix is available
None available
Currently no fix is available
Common Configurator on Device (CC on Edge)
Product Status: known_affected
Remediations
Mitigation
Stop Common Configurator on Device (CC on Edge) until a fix is available
None available
Currently no fix is available
Data Flow Monitoring < V3.0.18
Product Status: known_affected
Remediations
Vendor fix
Update to V3.0.18 or later version
Databus Configurator < V4.0.1
Product Status: known_affected
Remediations
Vendor fix
Update to V4.0.1 or later version
DataXess Configurator < V1.5.7
Product Status: known_affected
Remediations
Vendor fix
Update to V1.5.7 or later version
Edge OPC UA Server Configurator < V2.3.10
Product Status: known_affected
Remediations
Vendor fix
Update to V2.3.10 or later version
Flow Creator Configurator < V1.15.1
Product Status: known_affected
Remediations
Vendor fix
Update to V1.15.1 or later version
Industrial Edge Hub
Product Status: known_affected
Remediations
Vendor fix
Vulnerability fixed on central cloud service starting 2026-10-29; no user actions necessary
Additional Metrics
Relevant CWE: CWE-787 Out-of-bounds Write
CVSS Version
Base Score
Base Severity
Vector String
3.1
9.8
CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Acknowledgments
- Siemens ProductCERT reported this vulnerability to CISA.
General Recommendations
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity